Morton Buildings, Inc. - Excellence Since 1903 Morton Buildings, Inc. - Excellence Since 1903
Find A Construction Center
Nearest You!

DESIGN SPOTLIGHT

Fire Station

Caseville Fire Department

[-------------------]

.

Caseville Fire Department

Caseville, MI
Job# 62-3627-99
Photo# 2409

Fire Station Fire Station

.

Floor Plan

.

FUNCTIONAL FEATURES

  • Asphalt Shingled Roofs
  • Vented Ridgecap
  • (1) 3' 6" x 3' 6" Cupola
  • (1) EZ Mount Weather Station
  • Kynar 500® Sides and Ends
  • 2' Overhangs on Eaves
  • 8' Eyebrow Overhangs on Endwall Gables
  • 24" Fascia
  • Brick or Steel Wainscot
  • (6) 12' 2" x 14' Raynor® Tricore® Overhead Doors with Electric Operators, Button Controls and (3) 24" x 8" Lites
  • (7) Jamb Protectors
  • (2) Glass Entry Doors with 18" Sidelites, 10" Kick Panels, Closers, Push-Pull Hardware and Thumb Turn Locks
  • (6) Steel Walkdoors with Closers, Passage Lever Locksets and Deadbolts
  • (1) Embossed Steel Walkdoor with Closer, Passage Lever Lockset and Deadbolt
  • (1) Flush Steel Walkdoor with Closer, Passage Lever Lockset and Deadbolt
  • (2) Flush Steel Walkdoors with Keyed Lever Locksets
  • (13) Solid Core Interior Walkdoors
  • (13) 25" x 47" Pella® Casement Windows with Smart Sash, Screens and Slim Shades
  • (1) 47" x 15" Pella® Fixed Casement Window
  • Sprinkler System
  • Insulation
  • Gutters and Downspouts
  • Concrete Footings, Foundation and Floors
  • Steel Ceiling in Shop and Storage Areas
  • Steel and Acoustical Steel in Apparatus Room
  • Textone Vinyl Guypsum Wallboard and Oak Paneling Wainscot in Office Area
  • Suspended Ceiling in Office Area
  • Carpet or Excelon Floors with Oak or Vinyl Base Trims
  • Oak Kitchen and Bathroom Cabinets
  • Kitchen Appliances
  • Bathroom Fixtures
  • Electric, Heating, Air Conditioning and Plumbing
  • Site Preparation

PROJECT DELIVERY SYSTEM FEATURES

  • Analysis of Current and Future Program Needs
  • Evaluation of Budget Requirements
  • Review of Building and Life Safety Codes
  • Architectural, Structural, and Mechanical Plans and Specifications
  • Acoustical Analysis for Most Effective Acoustical Value is Available upon Request
  • Interior Layout and Selection of Life Cycle Cost Performance Components
[-------------------]

.

Request More Info

Inquiries will be served from corporate headquarters.


Design Team: Gary Koelzer-Sales Consultant, Ken Jackson-Design Estimator,
Jeff Geske-Construction Estimator

.


For more information call 1-800-447-7436 ext:285
Search · Financing · NEW Country Craft Product Line ·
Morton Buildings Honored · Gallery Of Beautiful Buildings · Calendar Photos ·
Color A Building · Contact Us · Current Job Openings ·
Home · Find A Local Morton Office · What's New ·
Manufacturing Locations · Request Info ·
Visit Us At The Shows · Customer Comments ·
Tour of the Month · Welcome to Morton Buildings About Us · Site Map ·
Building Collage · World Of Morton Buildings · Virtual Tours ·
Basic To Bold · Recent Advertisements · Other Site Links · Morton's Showcase ·

 

Copyright © 2007 Morton Buildings, Inc.